I have developed dense-packed unventilated roof assemblies various occasions without dilemma. Needless to say I have not torn into them possibly. I would want to see a lot more examples of failures in these kinds of assemblies if they're to choose from.

Your plan to set up a stack of rigid foam rectangles in each rafter bay is known as the "Lower-and-cobble" technique of insulation. It's a way usually preferred by homeowners, but never picked out by insulation contractors.

You do not need to work with insect display screen, simply because fiberglass batts need to be enclosed by an air barrier on both sides. Once the leading facet of fiberglass batts are subject matter to wind-washing, the moving air degrades the general performance from the insulation.

The longer that you wait to put in rigid foam earlier mentioned your roof sheathing after your rafter bays are filled with fluffy insulation, the increased the risk that your roof sheathing will accumulate humidity. A couple of yrs should be no dilemma, but I wouldn't stretch the exercise Considerably farther than that.

Your plan will get the job done fantastic, as long because the layer of rigid foam along with your roof sheathing has an R-worth of at least R-twenty. Should you be using XPS, you'll need at least four inches of foam. For anyone who is using polyisocyanurate, you may need at least navigate to this website 3 inches of foam.

You will be proposing a vented roof assembly. For your vented roof assembly, the code would not involve that any foam insulation be placed in immediate contact with your roof sheathing -- Quite the opposite.

Thanks, Martin and Stephen. Fortunately we've been in the situation in which we can pause and reconsider, as the new felt is put, Nevertheless they have not started putting in shingles yet. I will discuss the situation with the contractor again. I can be able to acquire him to reconsider.

A brand new standalone immediate vent fuel stove is going in for the much conclusion from the home beneath the metallic box. I figure if we use XPS board, it would need to be pulled back again a i thought about this number of inches from around that area, but I failed to Believe it will avoid me from using XPS completely. Looks like Roxul is significantly less of a difficulty when it comes to warmth/hearth.

The roof seems to possess a layer of asphalt shingles more than the sheathing with a tin roof above that. The soffits are shut off. The house is way from the overwhelmed route and It truly is difficult to visit this site get any contractors on the market to operate, not to mention present bids so I'm basically by myself.

Of course, it really is Harmless (Despite the fact that before you question a matter about a certain roof assembly, It could be great to find out your local climate zone).

My opinion is that the steep side of the mansard roof is actually a roof. This is often especially true if the exterior on the sloped assembly is finished with roofing.

Does this strategy seem as successful as vent channels created on the inside from the roof sheathing? I'm struggling to see why this wouldn't function as well or in nearly precisely the same way as an in-board website-created vent channel. It can be fundamentally just like a rain display or vented cavity, very same as within the partitions. Any feelings on this?

The perimeters in the roof are included with asphalt shingled (GAF Slateline to be specific). It feels like I ought to pull down the fiberglass and possess it spray-foamed right before I drywall.